Free Evaluation Scan

    We have several of our products available for demonstration. We are happy to provide a free demonstration on one of the instruments for new customers to help determine if the system is right for your application. If you'd like to request a free demo, please complete the form below:







    1-866-334-4MPI (4674)
    Home / Visque Systems Comparison

    Visque Systems Comparison

    VISQUE Bio-Imaging Systems Comparison Guide

     VISQUE™ InVivo EliteVISQUE™ InVivo SmartVISQUE™ InVivo Smart-LF
    Appearance
    Dimension (W x D x H)56 x 56 x 90 cm40 x 40 x 57 cm40 x 40 x 57 cm
    Weight> 100 kg17 kg22 kg
    Imaging Chamber Size
    (W x D x H)
    Imaging Bed Size (H x V)
    Display7" color LCD touch screen
    Power Requirements100 - 240 V AC, 50/60 Hz,
    max. 0.5 A at 220 V AC
    100 - 240 V AC, 50/60 Hz,
    max. 0.5 A at 220 V AC
    Operating Temperature10 ~ 30 ℃10 ~ 27 ℃10 ~ 27 ℃
    Environment1) Storage and Moving Temperature : 1 ~ 55 ℃
    2) Operating Humidity : 30 ~ 70 % (Non-condensing)
    3) Storage and Moving Humidity : 10 ~ 90 % (Non-condensing)
    1) Storage and Moving Temperature : 1 ~ 55 ℃
    2) Operating Humidity : 30 ~ 70 % (Non-condensing)
    3) Storage and Moving Humidity : 10 ~ 90 % (Non-condensing)
    Detector
    CameraVP-8MCVSP-4MU
    Sensorinterline CCD (KAI-08050)scientific CMOS (2MP)1.2" backside illuminated sCMOS (4MP)
    Cooling-10 ℃ (∆T = -20 ℃)-50 °C below ambient temperature
    thermoelectric peltier cooling
    Sensor Pixel1600 x 1200 (3296 x 2472)1024 x 1024 (2048 x 1152)1824 x 1824 (2048 x 2048)
    Sensor Size18.13 x 13.60 mm13.3 x 7.5 mm13.3 x 13.3 mm
    Pixel Size5.5 x 5.5 μm6.5 x 6.5 μm6.5 x 6.5 μm
    Frame Rateup to 24 fps30 fps37 fps
    Min. Image Pixel Resolution33 μm (at 6x)20 μm (at 7.5x)
    Full Well Capacity20,000 e-45,000 e-54,000 e-
    Quantum Efficiency43 % at 470 nm (blue)
    42 % at 540 nm (green)
    31 % at 620 nm (red)
    72 % at 595 nm94 % at 550 nm
    60 % at 800 nm
    Dark Current7 e/s/pixel (40 °C)< 10 e/s/pixel (@ 30 °C)100 e/s/pixel (@ 35 °C)
    0.2 e/s/pixel (@ -20 °C)
    Min. Detectable Radiance
    Binning1x1 ; 2x2 ; 4x41x1 ; 2x21x1 ; 2x2 ; 4x4
    Read Noise12 e- rms (f = 40 MHz)< 2 e-
    Dynamic Range64 dB87.5 dB90 dB
    Grayscale40961638465536
    Detection Spectral Range350 - 900 nm (> 5 %)500 ~ 900 nm300 ~ 920 nm
    Lensmax. ƒ/1.8, 10 steps zoom
    (motorized zooming lens)
    zoom range : 1x ~ 7.5xmax. ƒ/1.8, 5 steps zoom
    motorized zoom lens
    Field of View (H x V)28 x 21 cm ~ 5 x 4 cm
    (10 steps)
    Max. 15 x 15 cm
    Min. 2 x 2 cm
    Max. 15 x 15 cm
    Min. 5 x 5 cm
    Sensor Bit Depth12bit14bit16bit
    File Bit Depth (A/D)
    Excitation and Filter
    SourceLEDLEDLED
    Excitation Filters4 sets4 sets (optional)4 sets (optional)
    Excitation Filter Positions88
    Excitation Wavelength Range470 nm (blue)
    540 nm (green)
    620 nm (red)
    nm (far-red)
    nm (NIR)
    390 - 490 nm (blue)
    530 - 570 nm (green)
    620 - 650 nm (red)
    630 - 680 nm (hyperred)
    740 - 790 nm (NIR)
    390 - 490 nm (blue)
    530 - 570 nm (green)
    620 - 650 nm (red)
    630 - 680 nm (hyperred)
    740 - 790 nm (NIR)
    White Lightepi white LEDepi white LEDepi white LED
    Emission and Filter
    Filter Selectionautomatedautomatedautomated
    Emission Filters41 included1 included
    Emission Filter Positions1010 (8 optional)10 (8 optional)
    Emission Filter Wavelenth Range500 - 550 nm (GFP)
    575 - 640 nm (PE)
    690 - 740 nm (Cy5.5)
    810 - 860 nm (ICG)
    500 - 550 nm (GFP)
    575 - 640 nm (PE)
    690 - 740 nm (Cy5.5)
    810 - 860 nm (ICG)
    DyesGFP, EGFP, Alexa448, FITC, Fluorescein (Ex: 440 - 490 nm, Em: 515 - 575 nm)
    RFP, DsRed, PE, Alexa 568, mCherry (Ex: 500 - 545 nm, Em: 575 - 650 nm)
    Cy5.5, PKE680, Alexa 660 (Ex: 620 - 650 nm / 640 - 680 nm, Em: 700 - 770 nm)
    ICG, QD800 (Ex: 760 - 780 nm, Em: 810 - 870 nm)
    GFP / EGFP / Alexa 448 / FITC / QD 525
    RFP / DsRed / PE / Alexa 568 / TRITC / QD 585 / QD 605 / QD 625
    Cy5.5 / PKE680 / Alexa 680 / Alexa 700 / QD 705
    ICG / QD 800
    GFP / EGFP / Alexa 448 / FITC / QD 525
    RFP / DsRed / PE / Alexa 568 / TRITC / QD 585 / QD 605 / QD 625
    Cy5.5 / PKE680 / Alexa 680 / Alexa 700 / QD 705
    ICG / QD 800
    Imaging Stage & Anesthesia
    Animal Capacity5 mice
    1 mouse
    1 rat
    up to 3 miceup to 3 mice
    Heating ModuleYesNoYes (optional)
    Imaging Bed Temperature RangeOff, 25 ℃, 36 ℃Off, 36 ℃
    Gas AnesthesiaYesYes (optional)Yes (optional)
    Additional Features1) Kinetics Analysis : duplicate (inner & outer) doors and Y axis sliding stage system
    2) Stage Types : 3-type stages (5-mice / 1-mouse / 1-rat)
    1) Anesthesia Ventilator Adapter, Heating Stage : Desinged to work together with third-party equipment
    Application
    Applicationsfluorescence
    bioluminescence
    real-time imaging
    preview capture
    oncology
    infectious diseases
    stem cell biology
    neuroscience
    cardiovascular
    metabolic diseases
    gene therapy
    inflammation research
    immunology
    fluorescence
    luminescence

    pharmacology
    toxicology
    oncology
    cardiovascular function
    photo-stability test of molecules
    cell therapy test
    biodistribution of nanoparticle
    Acquisition
    Min. Exposure time1 ms13 ms25ms
    Max. Exposure time50 min3 s15 min
    Kinetic ImagingYesYesYes
    Exposure Modessingle frame
    time lapse
    accumulation
    single frame
    time lapse
    single frame
    time lapse
    accumulation
    Control & Analysis
    Analysis ToolVISQUE CleVue™VISQUE CleVue™ 2.0VISQUE CleVue™ 3.0
    Web Sitehttp://www.vieworks.com/product.html?pid=47http://www.vieworks.com/product.html?pid=47http://www.vieworks.com/product.html?pid=47
    License2 copies included2 licenses included2 licenses included
    Spectral Unmixing
    Featureskinetics and radiance analysiskinetics and radiance analysiskinetics and radiance analysis
    Computer Requirements1) OS : Windows 7 Professional 64bit, Windows 10 Professional 64bit
    2) CPU : Intel Core i7-6700K CPU @ 4.0 GHz
    3) SSD : Write speed above 400 MB/s
    4) Memory : Above 16 GB
    5) USB expansion card : NETmate U-1130 USB3.1 Dual Type-A PCIe card (dedicated for InVivo Smart communication, provided by Vieworks)
    1) OS : Windows 7 Professional 64bit, Windows 10 Professional 64bit
    2) CPU : Intel Core i7-6700K CPU @ 4.0 GHz
    3) SSD : Write speed above 400 MB/s
    4) Memory : Above 16 GB
    5) USB expansion card : NETmate U-1130 USB3.1 Dual Type-A PCIe card (dedicated for InVivo Smart communication, provided by Vieworks)
    Computer InterfaceethernetUSB 3.0USB 3.0
    Computer SuppliedYesYesYes
    VISQUE offers three systems with various features for you to select from in choosing the most appropriate bio-imaging system for your research.

    Request more information