Free Evaluation Scan

We have several of our products available for demonstration. We are happy to provide a free demonstration on one of the instruments for new customers to help determine if the system is right for your application. If you'd like to request a free demo, please complete the form below:







1-866-334-4MPI (4674)
Home / Visque Systems Comparison

Visque Systems Comparison

VISQUE Bio-Imaging Systems Comparison Guide

 VISQUE™ InVivo EliteVISQUE™ InVivo SmartVISQUE™ InVivo Smart-LF
Appearance
Dimension (W x D x H)56 x 56 x 90 cm40 x 40 x 57 cm40 x 40 x 57 cm
Weight> 100 kg17 kg22 kg
Imaging Chamber Size
(W x D x H)
Imaging Bed Size (H x V)
Display7" color LCD touch screen
Power Requirements100 - 240 V AC, 50/60 Hz,
max. 0.5 A at 220 V AC
100 - 240 V AC, 50/60 Hz,
max. 0.5 A at 220 V AC
Operating Temperature10 ~ 30 ℃10 ~ 27 ℃10 ~ 27 ℃
Environment1) Storage and Moving Temperature : 1 ~ 55 ℃
2) Operating Humidity : 30 ~ 70 % (Non-condensing)
3) Storage and Moving Humidity : 10 ~ 90 % (Non-condensing)
1) Storage and Moving Temperature : 1 ~ 55 ℃
2) Operating Humidity : 30 ~ 70 % (Non-condensing)
3) Storage and Moving Humidity : 10 ~ 90 % (Non-condensing)
Detector
CameraVP-8MCVSP-4MU
Sensorinterline CCD (KAI-08050)scientific CMOS (2MP)1.2" backside illuminated sCMOS (4MP)
Cooling-10 ℃ (∆T = -20 ℃)-50 °C below ambient temperature
thermoelectric peltier cooling
Sensor Pixel1600 x 1200 (3296 x 2472)1024 x 1024 (2048 x 1152)1824 x 1824 (2048 x 2048)
Sensor Size18.13 x 13.60 mm13.3 x 7.5 mm13.3 x 13.3 mm
Pixel Size5.5 x 5.5 μm6.5 x 6.5 μm6.5 x 6.5 μm
Frame Rateup to 24 fps30 fps37 fps
Min. Image Pixel Resolution33 μm (at 6x)20 μm (at 7.5x)
Full Well Capacity20,000 e-45,000 e-54,000 e-
Quantum Efficiency43 % at 470 nm (blue)
42 % at 540 nm (green)
31 % at 620 nm (red)
72 % at 595 nm94 % at 550 nm
60 % at 800 nm
Dark Current7 e/s/pixel (40 °C)< 10 e/s/pixel (@ 30 °C)100 e/s/pixel (@ 35 °C)
0.2 e/s/pixel (@ -20 °C)
Min. Detectable Radiance
Binning1x1 ; 2x2 ; 4x41x1 ; 2x21x1 ; 2x2 ; 4x4
Read Noise12 e- rms (f = 40 MHz)< 2 e-
Dynamic Range64 dB87.5 dB90 dB
Grayscale40961638465536
Detection Spectral Range350 - 900 nm (> 5 %)500 ~ 900 nm300 ~ 920 nm
Lensmax. ƒ/1.8, 10 steps zoom
(motorized zooming lens)
zoom range : 1x ~ 7.5xmax. ƒ/1.8, 5 steps zoom
motorized zoom lens
Field of View (H x V)28 x 21 cm ~ 5 x 4 cm
(10 steps)
Max. 15 x 15 cm
Min. 2 x 2 cm
Max. 15 x 15 cm
Min. 5 x 5 cm
Sensor Bit Depth12bit14bit16bit
File Bit Depth (A/D)
Excitation and Filter
SourceLEDLEDLED
Excitation Filters4 sets4 sets (optional)4 sets (optional)
Excitation Filter Positions88
Excitation Wavelength Range470 nm (blue)
540 nm (green)
620 nm (red)
nm (far-red)
nm (NIR)
390 - 490 nm (blue)
530 - 570 nm (green)
620 - 650 nm (red)
630 - 680 nm (hyperred)
740 - 790 nm (NIR)
390 - 490 nm (blue)
530 - 570 nm (green)
620 - 650 nm (red)
630 - 680 nm (hyperred)
740 - 790 nm (NIR)
White Lightepi white LEDepi white LEDepi white LED
Emission and Filter
Filter Selectionautomatedautomatedautomated
Emission Filters41 included1 included
Emission Filter Positions1010 (8 optional)10 (8 optional)
Emission Filter Wavelenth Range500 - 550 nm (GFP)
575 - 640 nm (PE)
690 - 740 nm (Cy5.5)
810 - 860 nm (ICG)
500 - 550 nm (GFP)
575 - 640 nm (PE)
690 - 740 nm (Cy5.5)
810 - 860 nm (ICG)
DyesGFP, EGFP, Alexa448, FITC, Fluorescein (Ex: 440 - 490 nm, Em: 515 - 575 nm)
RFP, DsRed, PE, Alexa 568, mCherry (Ex: 500 - 545 nm, Em: 575 - 650 nm)
Cy5.5, PKE680, Alexa 660 (Ex: 620 - 650 nm / 640 - 680 nm, Em: 700 - 770 nm)
ICG, QD800 (Ex: 760 - 780 nm, Em: 810 - 870 nm)
GFP / EGFP / Alexa 448 / FITC / QD 525
RFP / DsRed / PE / Alexa 568 / TRITC / QD 585 / QD 605 / QD 625
Cy5.5 / PKE680 / Alexa 680 / Alexa 700 / QD 705
ICG / QD 800
GFP / EGFP / Alexa 448 / FITC / QD 525
RFP / DsRed / PE / Alexa 568 / TRITC / QD 585 / QD 605 / QD 625
Cy5.5 / PKE680 / Alexa 680 / Alexa 700 / QD 705
ICG / QD 800
Imaging Stage & Anesthesia
Animal Capacity5 mice
1 mouse
1 rat
up to 3 miceup to 3 mice
Heating ModuleYesNoYes (optional)
Imaging Bed Temperature RangeOff, 25 ℃, 36 ℃Off, 36 ℃
Gas AnesthesiaYesYes (optional)Yes (optional)
Additional Features1) Kinetics Analysis : duplicate (inner & outer) doors and Y axis sliding stage system
2) Stage Types : 3-type stages (5-mice / 1-mouse / 1-rat)
1) Anesthesia Ventilator Adapter, Heating Stage : Desinged to work together with third-party equipment
Application
Applicationsfluorescence
bioluminescence
real-time imaging
preview capture
oncology
infectious diseases
stem cell biology
neuroscience
cardiovascular
metabolic diseases
gene therapy
inflammation research
immunology
fluorescence
luminescence

pharmacology
toxicology
oncology
cardiovascular function
photo-stability test of molecules
cell therapy test
biodistribution of nanoparticle
Acquisition
Min. Exposure time1 ms13 ms25ms
Max. Exposure time50 min3 s15 min
Kinetic ImagingYesYesYes
Exposure Modessingle frame
time lapse
accumulation
single frame
time lapse
single frame
time lapse
accumulation
Control & Analysis
Analysis ToolVISQUE CleVue™VISQUE CleVue™ 2.0VISQUE CleVue™ 3.0
Web Sitehttp://www.vieworks.com/product.html?pid=47http://www.vieworks.com/product.html?pid=47http://www.vieworks.com/product.html?pid=47
License2 copies included2 licenses included2 licenses included
Spectral Unmixing
Featureskinetics and radiance analysiskinetics and radiance analysiskinetics and radiance analysis
Computer Requirements1) OS : Windows 7 Professional 64bit, Windows 10 Professional 64bit
2) CPU : Intel Core i7-6700K CPU @ 4.0 GHz
3) SSD : Write speed above 400 MB/s
4) Memory : Above 16 GB
5) USB expansion card : NETmate U-1130 USB3.1 Dual Type-A PCIe card (dedicated for InVivo Smart communication, provided by Vieworks)
1) OS : Windows 7 Professional 64bit, Windows 10 Professional 64bit
2) CPU : Intel Core i7-6700K CPU @ 4.0 GHz
3) SSD : Write speed above 400 MB/s
4) Memory : Above 16 GB
5) USB expansion card : NETmate U-1130 USB3.1 Dual Type-A PCIe card (dedicated for InVivo Smart communication, provided by Vieworks)
Computer InterfaceethernetUSB 3.0USB 3.0
Computer SuppliedYesYesYes
VISQUE offers three systems with various features for you to select from in choosing the most appropriate bio-imaging system for your research.

Request more information