Welcome to Micro Photonics Home Page
 

Dynamic X-Ray Imaging Cameras

The X-Ray Imager series of cameras from Photonic Science are dynamic imaging X- ray cameras each comprising a particular combination of scintillator with fiber optic coupling to a CCD chip. These cameras offer distinct advantages over film techniques for many experimental situations involving dynamic imaging.   
 
X-Ray imager camera
 X-Ray Imager Video Camera

Features of the X-Ray Imager Cameras

  • 5 keV to 100 keV coverage
  • Real time X- Ray video imaging
  • Observe images during integration - at low flux levels
  • Observe details much more quickly than with film
  • Easy to use - complete with power supply and software


 Visit our X-Ray Micro-CT page

X-Ray Imager Models

Model UHR  Ultra High Resolution Imager offers better than 10 microns resolution from a 768 x 494 CCD with 6.5 micron pixels. This new camera has a 6 mm image diagonal with a 4:3 aspect ratio.
Model SHR Super High Resolution is designed specifically designed from low energy X-Ray studies where resolution is critical. Ideally suited for CuK alpha radiation the 18 micron resolution provides superbly detailed images in topography and micro-radiography
Model HR High Resolution cameras
Is a real time X - ray video imaging camera for use where high spatial resolution (< 30 um) is required over a wide range of X ray intensities.

X-Ray Imager standard camera
Offers a large 50 mm diagonal with < 80 um resolution over a wide energy range and, optionally, with interchangeable scintillators
X-Ray Imager LA large area camera
 Acquires images on a large 115 mm diagonal with the same 5 keV - 100 keV energy range. This unit is ideal for wide angle real time X-Ray imaging , particularly at low energies where conventional X-Ray intensifiers are unable to function.
 

X-Ray Imager Specifications

X-Ray Scintillator Polycrystalline gadolinium oxysulphide
Energy response 5 - 100 keV
Input Window 10 um aluminum
Image Format Rectangular, 4:3 aspect ratio
Coupling Coherent fiber optic
Video Standards EIA 525 lines/60 Hz 
Sync in/out negative compound TTL
Protection Automatic over-illumination protection
Gain Range 1000:1
Gain Control User controlled or automatic (AGC)
Power Requirements 110/V AC
Temperature Range -5 to + 55 deg C
Humidity Up to 70 % R


Model Specific Specifications

Camera Type UHR Imager SHR Imager HR Imager Imager LA Imager
Image diagonal 6 mm 11 mm 18 mm 50 mm 115 mm
Resolution < 10 microns < 18 microns < 30 microns < 80 microns < 150 microns
Active area (h x v) (mm) 4.8 x 3.6 8.8 x 6.6 14.4 x 10.8 40 x 30 92 x 69

| Related Products | Home Page | Online Request | Email |

 Visit our X-Ray Micro-CT page

Micro Photonics Inc.
PO Box 3129
Allentown, PA 18106-0129
Tel: (610) 366-7103 Fax: (610) 366-7105 E-Mail

info@microphotonics.com