SkyScan X-ray Microtomography |
|
|
|
The capabilities of the SkyScan X-ray Microtomograph go well beyond just amazing X-ray images. A uniquely designed software package provides all the necessary tools you need to extract the most vital information out of your data set. Easy-to-use interfaces and robust features make 2-dimensional and 3-dimensional analysis of internal structures simple and accurate. Skip To: Acquisition, Reconstruction, Visualization, 3D Analysis and Modeling, Bone Analysis Software, MIP |
![]() |
![]() |
![]() |
|
|
||||||||
All SkyScan
micro-CTs are supplied with user friendly, PC based acquisition software.
Control software is also included with the special purpose stages (cooling
stage, material testing stage, and micro-positioning stage) for the
1172 and 1174 . |
|||||||||
SkyScan's volumetric reconstruction software "Nrecon" uses the set of acquired angular projections to create a set of cross section slices through the object. The program uses a modified Feldkemp algorithm with automatic adaptation to the scan geometry in each micro-CT scanner. Reconstructed slices can be saved in BMP, TIFF, JPG or numerical data format. The program can run on one PC or distribute the reconstruction across a cluster of several networked PCs working in parallel to achieve exceptional speed. Nrecon measures and adapts to differences in computer performance and network connection for equitable job distribution. Reconstruction includes beam-hardening correction, alignment optimization, ring artifact correction, reconstruction in a restricted volume of interest, reconstruction of objects wider than the field of view, external and internal calibration into Housfield units and interactive density window selection. |
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
Nrecon
accepts large format angular projection images to reconstruct cross
section images with up to 8000 x 8000 pixels. User-friendly batch processing
allows many reconstruction jobs with different settings to be run sequentially
without operator input. |
||||||||||||||||||||||||||||||||||||||||
The reconstructed set of slices can be flexibly viewed in SkyScan's DataViewer software program. Images are displayed as a slice-by-slice movie or as three orthogonal sections, centered at any selected point inside the reconstructed space. DataViewer also has a viewing mode with three intersecting orthogonal sections, which can be turned and each intersecting slice independently moved by simple mouse control. |
|
|
|
Additional
features include variable smoothing, saving interpolated data sets in
saggital or coronal section, measuring and saving distances and intensity
profiles. The format converter utility "T-conv" converts between
TIFF, BMP, and JPEG files with adjustment of color palette, inversion,
renaming, resizing, and combining of data sets |
|
All
SkyScan scanners are equipped with a software package for complete 2D
and 3D quantitative analysis of reconstructed volumes from micro-CT
scans, the program CT-Analyzer, and software for realistic
3D visualization of scanned objects, the CT-Volume program.
These programs can run on the supplied workstation or on any of your
laboratory's desktop or notebook computers. |
|||
![]() |
|||
CTAn analyzes micro-CT data sets for morphometry and densitometry. It is an intuitive and comprehensive environment for processing and analyzing data sets, accurately generating the quantitative data that is the final objective of micro-CT scanning. |
|||
| Software
for bone analysis Skyscan has developed software specifically designed for analyzing bone and similar structures. You can quickly analyze the series of slices individually or as a 3D volume. Using the Skyscan micro-CTs with their CT-analysis software, you can calculate: |
|||
With
region of interest selection by either circle , ellipse or free hand
drawing, you can make sure you are only analyzing the appropriate areas
of your samples.
Visit
the applications pages |
|||
![]() |
|
| Mouse lower leg infiltrated with gel+Ba2SO4. Skyscan 1172, 8µm pixel | |
|
|
| Burdock | |
![]() |
|
| Rabbit kidney infiltrated with microfil. Skyscan 1172, 4 µm pixel size. | |
![]() |
|
| Mouse brain infiltrated with microfil. Skyscan 1172, 4 µm pixel | |